Если вам необходимо проверить все сервисы в Linux, сделать это можно быстро командой:
# service —status-all
Выводом будет подробная информация о системе:
….
…..
irqbalance (pid 2183) is running…
iscsi is stopped
iscsid is stopped
Kdump is operational
i5k_amb-isa-0000
Adapter: ISA adapter
Ch. 0 DIMM 0: +63.0°C  (low  = +127.5°C, high = +127.5°C)  
Ch. 0 DIMM 1: +56.5°C  (low  = +127.5°C, high = +127.5°C)  
Ch. 1 DIMM 0: +62.0°C  (low  = +127.5°C, high = +127.5°C)  
Ch. 1 DIMM 1: +49.0°C  (low  = +127.5°C, high = +127.5°C)  
Ch. 2 DIMM 0: +54.0°C  (low  = +127.5°C, high = +127.5°C)  
Ch. 3 DIMM 0: +49.0°C  (low  = +127.5°C, high = +127.5°C)  
 
coretemp-isa-0000
Adapter: ISA adapter
Core 0:      +37.0°C  (high = +78.0°C, crit = +100.0°C)  
Core 1:      +38.0°C  (high = +78.0°C, crit = +100.0°C)  
Core 2:      +34.0°C  (high = +78.0°C, crit = +100.0°C)  
Core 3:      +38.0°C  (high = +78.0°C, crit = +100.0°C)  
 
coretemp-isa-0001
Adapter: ISA adapter
Core 0:      +40.0°C  (high = +78.0°C, crit = +100.0°C)  
Core 1:      +40.0°C  (high = +78.0°C, crit = +100.0°C)  
Core 2:      +39.0°C  (high = +78.0°C, crit = +100.0°C)  
Core 3:      +39.0°C  (high = +78.0°C, crit = +100.0°C)  
 
w83627hf-isa-0290
Adapter: ISA adapter
in0:         +4.08 V  (min =  +0.00 V, max =  +4.08 V)   
in1:         +4.08 V  (min =  +0.00 V, max =  +4.08 V)   
in2:         +4.08 V  (min =  +2.82 V, max =  +3.79 V)   ALARM
in3:         +3.07 V  (min =  +4.08 V, max =  +4.05 V)   ALARM
in4:         +3.12 V  (min =  +4.08 V, max =  +4.08 V)   ALARM
in5:         +3.15 V  (min =  +4.08 V, max =  +4.06 V)   ALARM
in6:         +3.20 V  (min =  +4.08 V, max =  +4.06 V)   ALARM
in7:         +3.28 V  (min =  +3.82 V, max =  +4.06 V)   ALARM
in8:         +3.28 V  (min =  +4.06 V, max =  +4.06 V)   ALARM
fan1:          0 RPM  (min =    0 RPM, div = 2)
fan2:          0 RPM  (min =    0 RPM, div = 2)
fan3:          0 RPM  (min =    0 RPM, div = 2)
temp1:       -48.0°C  (high = +60.0°C, hyst = +55.0°C)  sensor = thermistor
temp2:       -48.0°C  (high = +80.0°C, hyst = +75.0°C)  sensor = thermistor
temp3:       -48.0°C  (high = +80.0°C, hyst = +75.0°C)  sensor = thermistor
cpu0_vid:   +1.419 V
beep_enable:enabled
 
lvmetad is stopped
mdmonitor is stopped
memcached (pid  45560) is running…
messagebus (pid  7066) is running…
mysqld (pid  7556) is running…
netconsole module not loaded
Configured devices:
lo eth0 eth1
Currently active devices:
lo eth0 eth1
rpc.svcgssd is stopped
rpc.mountd (pid 7199) is running…
nfsd (pid 7262 7261 7260 7259 7258 7257 7256 7255) is running…
rpc.rquotad (pid 7195) is running…
rpc.statd (pid  2215) is running…
ntpd (pid  7295) is running…
master (pid  7649) is running…
Process accounting is enabled.
ipmi_msghandler module not loaded.
ipmi_si module not loaded.
ipmi_devintf module not loaded.
/dev/ipmi0 does not exist.
quota_nld is stopped
rdisc is stopped
…..
..